At present, if there are hand warmers, mobile phone batteries, chargers or other live products sold on the Amazon website, they must meet the specified certification standards. If these standards are not met, Amazon may revoke the seller's sales authority. It is understood that if such products are unqualified, it is easy to cause fire and endanger people's lives and property safety. Similar cases have occurred before! Since the UL standard is also the safety testing standard in the Americas, Amazon will strengthen the control of live electrical and electronic products for safety reasons, and many products have been removed from the shelves, which is reasonable.
It is undeniable that product certification is no longer a new topic, and Amazon's review of live products is even more stringent, and the large number of the above-mentioned emails sent by Amazon this time is more of a reminder for sellers. "In order to ensure the safety of consumers, Amazon always emphasizes that live products need to have relevant certification before they can be sold, and live products need to be issued by a laboratory accredited by ILAC ISO 17025 or NRTL authorized standards.
182 0070 0074 Forestry
Today, I will explain in detail some of the main test items for the UL130 certification of the cushion heater:
1. Thermostat test
1. Calibration test;
2. Overload test;
3. Durability test;
4. Recalibration test;
Second, the shell material
1. Low temperature impact test;
2. Tear resistance test;
3. Leakage current test;
4. Repeat the leakage current test;
5. Shrinkage test;
6. Physical performance test;
7. Tensile strength test at seams;
3. Flammability test;
1. The bushing (tested according to UL94 standard), its burning rate should not exceed /min;
2. Prepare 10 samples of the outer cover for glow wire test, no two or more samples can be scorched or burned
Fourth, flame retardant test
Prepare 6 samples with a length of 200mm and a width of 100mm, put them on the instrument for testing, and energize them for 120 seconds. If all samples burn for more than 30 seconds after the energization test, the test will pass, otherwise the test will fail;
UL130 standard application process:
1. Fill in the application form,
2. Provide product information,
3. Send samples,
4. Test OK,
5. UL report/certification